The ultra-stable measurement solutions based on liqiud Helium systems

This system is based on a liquid Helium bath cryostat and has been optimized for highest stability. This system enables e.g. ultra high resolution imaging using Scanning Tunneling Microscopy (STM) or long-term investigations of single quantum dots over several weeks. A large variety of microscopy and probing heads cover a broad spectrum of measurement tasks. Superconducting magnets up to 15 T are available with this system.
Three LTSYS-He systems are available:

LTSYS-He4:
Dependent on the pumping system, temperatures down to 1.5 K can be achieved.
With an additional heating stage the temperature of the sample can be swept up to 70 K. A Variable Temperature Insert (VTI, optional) enables sweeping the temperature between 1.8 and 300 K.

LTSYS-He3:
Operating down to 300 mK, this state of the art system features integrated designs for the He3 insert with the high efficiency He bath cryostat. Reduction of the vapor
pressure is achieved by an internal sorption pump (charcoal cooling) optimized for lowest vibrations.

LTSYS-DIL:
Operating down to 20 mK, this state of the art system features lowest base temperatures for combination with e.g. the confocal microscopy insert attoCFM II.

The basic system includes the following components

liquid Helium bath cryostat with a 2“ insert fitting all attocube microscope and probing inserts
vibration and acoustic noise dampening system attoDAMP™ enabling
high resolution imaging
high-end SPM controller ASC500 or confocal microscopy controller ASC400 for intuitive controlling of the microcope modules.
piezo Scan Controller for fine scanning of the sample.
piezo Step Controller for sample coarse positioning.
workstation PC with TFT-monitor.


Options

sample heating stage for temperature control from 1.5 to 70 K
variable Temperature Insert (VTI) for temperature control from
1.8 to 300 K
He3 insert for base temperatures down to 300 mK
superconducting magnets up to 12 T by default (15 T on request)


Download:
Detailed Specification Sheet - LTSYS-He4
Detailed Specification Sheet - LTSYS-He3

Request Quotation & Support :

Available Measurement Heads:
Scanning Tunneling Microscopes; STM
Atomic Force Microscopes, AFM
Confocal Microscopes, CFM
Scanning Nearfield Optical Microscopes, SNOM
Cryogenic Probe Stations